Product Description
Split PVC Conduit Repair Kits by Prime Conduit
Fast and easy repair of broken duct and conduit without disturbing the installed wire/cable system. No costly cutting and re-splicing of your conductors. Prime Conduit's (Carlon) split kits are designed to maintain the same peformance and characteristics of the PVC pipe that is being repaired.Model: SK4020
- Size: 2”
- Wall Type: Schedule 40
- UPC Number: 670648190083
- Qty/Carton: 10
- Std. Ctn. Wt. (lbs.): 24.3
- Size: 2-1/2”
- Wall Type: Schedule 40
- UPC Number: 670648190090
- Qty/Carton: 10
- Std. Ctn. Wt. (lbs.): 249.2
- Size: 3”
- Wall Type: Schedule 40
- UPC Number: 670648190106
- Qty/Carton: 8
- Std. Ctn. Wt. (lbs.): 243.6
- Size: 4”
- Wall Type: Schedule 40
- UPC Number: 670648190113
- Qty/Carton: 5
- Std. Ctn. Wt. (lbs.): 240.5
- Size: 5”
- Wall Type: Schedule 40
- UPC Number: 670648190120
- Qty/Carton: 3
- Std. Ctn. Wt. (lbs.): 234.6
- Size: 6”
- Wall Type: Schedule 40
- UPC Number: 670648190137
- Qty/Carton: 2
- Std. Ctn. Wt. (lbs.): 236.4
- Size: 4”
- Wall Type: Type C
- UPC Number: 670648190144
- Qty/Carton: 5
- Std. Ctn. Wt. (lbs.): 236.2
Split Kit Features:
- Manufactured from extra rugged PVC material
- Specifically designed to make Schedule 40 conduit and Type C Telephone Duct repairs
- Convenient and handy 2 feet lengths for easy handling, transport and storage - and eliminates the need to cut 10' lengths to size
- Two 7" split couplings for a secure fit. Allows the product to be coupled together for longer repairs
- UV resistant for outdoor use
- Durable tongue and groove design that holds the true dimensions of the product, both I.D. and O.D., while maintaining the pipe’s physical performance characteristics
- Lightweight, solvent cementable and compatible with all standard pipe fittings
Split Kit Q&A
Does the split duct go over the conduit?No, it is designed to butt up against the conduit and the split couplings go over the outside of the split duct and conduit being repaired.
What are the standards for split duct?
There are no standards for split duct, so it does not have a full ETL/UL listing. Generally, it is used by telecomm companies or utilies that do not require a ETL/UL listing. Some inspectors have allowed non-listed split duct to be used based on Section 90.4 of the NEC. Special permission should always be obtain prior to the installation.
Can Split Kits be used with poured concrete?
Prime Conduit (Carlon) does not recommend pouring concrete over split duct and kits.
Can Split Kits be used in below ground installations?
Prime Conduit’s (Carlon) Schedule 40 Split conduit repair kits (SK4020, SK4025, SK4030, SK4040, SK4050, & SK4060) are designed for use with both rigid PVC nonmetallic Schedule 40 and Schedule 80 Conduit in both above ground and below ground installations.